Jaydeep Engineering Co.
Products /

Fire Pump

FIRE PUMPS, SPLIT CASE CENTRIFUGAL PUMPS AND BACK PULLOUT [HORIZONTAL AND VERTICAL].

Fire Pump

We supply fire pumps for practically all duty points with or without the jockey pump, for industry, building, shipping, offshore services, emergency fire pumps, emergency fire pumps for ship, FI FI pumps

Prime movers can be Diesel or Petrol Engine, Three phase or Single phase Electric Motor.

Sets are available with 50 or 60 Hz. Available for a wide range of input voltages from 110/220/300/400/440/500 Volts.

Range

Capacity
:
10 m3 per hour to 5,000 m3 per hour.
Head
:
upto 100m (also upto 220m with multistage design). Please see table below.
Speed
:
Upto 3500rpm.
Size
:
25 to 400 mm.
Type
:
upto 100m (also upto 220m with multistage design). Please see table below.

Special Designs for Ship's fire pumps, Fifi 1, Fifi 2, Fifi 3, etc.

With Kumera/Jason/Hitech Gear Box or Direct Coupled.

We have an excellent design back-up. For any application and duty point, We will design and supply pumps, if the same are not already in our range.

We supply pumps with a variety of construction features such as

Side Suction
:
Side Discharge
End Suction
:
Top Discharge
Side Suction [Left or Right]
:
Top Discharge.
Bottom Suction
:
Top discharge or Side discharge.

Clockwise or Anti clockwise Rotation.

Sr. No. Flow (m3/hr) Flow LPS/ LPM. Head in mts. RPM Prime Mover.
1. 97m3/hr 1620 LPM / 27 LPS 56 1500 Motor Drive/Diesel Driven
  97m3/hr 1620 LPM / 27LPS 56 1800 Motor Drive/Diesel Driven
  97m3/hr 1620 LPM / 27LPS 56 2000 Diesel Driven
  97m3/hr 1620 LPM / 27LPS 56 2200 Diesel Driven
  97m3/hr 1620 LPM / 27LPS 56 1500 Motor Drive/Diesel Driven
  97m3/hr 1620 LPM / 27LPS 56 1800 Motor Drive/Diesel Driven
2. 97m3/hr 1620 LPM / 27LPS 70 2000 Diesel Driven
  97m3/hr 1620 LPM / 27LPS 70 2200 Diesel Driven
  97m3/hr 1620 LPM / 27LPS 70 1500 Motor Drive/Diesel Driven
  97m3/hr 1620 LPM / 27LPS 70 1800 Motor Drive/Diesel Driven
  97m3/hr 1620 LPM / 27LPS 70 2000 Diesel Driven
  97m3/hr 1620 LPM / 27LPS 70 2200 Diesel Driven
3. 137m3/hr 2285LPM / 38 LPS 70 1500 Motor Drive/Diesel Driven
  137m3/hr 2285LPM / 38 LPS 70 1800 Motor Drive/Diesel Driven
  137m3/hr 2285LPM / 38 LPS 70 2000 Diesel Driven
  137m3/hr 2285LPM / 38 LPS 70 2200 Diesel Driven
  137m3/hr 2285LPM / 38 LPS 70 1500 Motor Drive/Diesel Driven
4. 137m3/hr 2285LPM / 38 LPS 88 1800 Motor Drive/Diesel Driven
  137m3/hr 2285LPM / 38 LPS 88 2000 Diesel Driven
  137m3/hr 2285LPM / 38 LPS 88 2200 Diesel Driven
  137m3/hr 2285LPM / 38 LPS 88 1500 Motor Drive/Diesel Driven
  137m3/hr 2285LPM / 38 LPS 88 1800 Motor Drive/Diesel Driven
5. 171m3/hr 2850LPM /48LPS 70 2000 Diesel Driven
  171m3/hr 2850LPM /48LPS 70 2200 Diesel Driven
  171m3/hr 2850LPM /48LPS 70 1500 Motor Drive/Diesel Driven
  171m3/hr 2850LPM /48LPS 70 1800 Motor Drive/Diesel Driven
6. 171m3/hr 2850LPM /48LPS 88 2000 Diesel Driven
  171m3/hr 2850LPM /48LPS 88 2200 Diesel Driven
7. 171m3/hr 2850LPM /48LPS 105 1500 Motor Drive/Diesel Driven
  171m3/hr 2850LPM /48LPS 105 1800 Motor Drive/Diesel Driven
  171m3/hr 2850LPM /48LPS 105 2000 Diesel Driven
  171m3/hr 2850LPM /48LPS 105 2200 Diesel Driven
8. 171m3/hr 2850LPM /48LPS 120 1500 Motor Drive/Diesel Driven
  171m3/hr 2850LPM /48LPS 120 1800 Motor Drive/Diesel Driven
9. 273m3/hr 4550LPM /76LPS 70 2000 Diesel Driven
  273m3/hr 4550LPM /76LPS 70 2200 Diesel Driven
  273m3/hr 4550LPM /76LPS 70 1500 Motor Drive/Diesel Driven
  273m3/hr 4550LPM /76LPS 70 1800 Motor Drive/Diesel Driven
10. 273m3/hr 4550LPM /76LPS 88 2000 Diesel Driven
  273m3/hr 4550LPM /76LPS 88 2200 Diesel Driven
  273m3/hr 4550LPM /76LPS 88 1500 Motor Drive/Diesel Driven
  273m3/hr 4550LPM /76LPS 88 1800 Motor Drive/Diesel Driven
  273m3/hr 4550LPM /76LPS 88 2000 Diesel Driven
11. 273m3/hr 4550LPM /76LPS 105 2200 Diesel Driven
  273m3/hr 4550LPM /76LPS 105 1500 Motor Drive/Diesel Driven
  273m3/hr 4550LPM /76LPS 105 1800 Motor Drive/Diesel Driven
12. 273m3/hr 4550LPM /76LPS 120 2000 Diesel Driven
  273m3/hr 4550LPM /76LPS 120 2200 Diesel Driven
13. 410m3/hr 6835LPM/114LPS 70 1500 Motor Drive/Diesel Driven
  410m3/hr 6835LPM/114LPS 88 1800 Motor Drive/Diesel Driven
  410m3/hr 6835LPM/114LPS 70 2000 Diesel Driven
  410m3/hr 6835LPM/114LPS 88 2200 Diesel Driven
14. 410m3/hr 6835LPM/114LPS 105 1500 Motor Drive/Diesel Driven
  410m3/hr 6835LPM/114LPS 105 1800 Motor Drive/Diesel Driven
  410m3/hr 6835LPM/114LPS 105 2000 Diesel Driven
  410m3/hr 6835LPM/114LPS 105 2200 Diesel Driven
15. 615m3/hr 1025LPM/170LPS 88 1500 Motor Drive/Diesel Driven
  615m3/hr 1025LPM/170LPS 88 1800 Motor Drive/Diesel Driven
  615m3/hr 1025LPM/170LPS 88 2000 Diesel Driven
  615m3/hr 1025LPM/170LPS 88 2200 Diesel Driven
16. 615m3/hr 1025LPM/170LPS 105 1500 Motor Drive/Diesel Driven
  615m3/hr 1025LPM/170LPS 105 1800 Motor Drive/Diesel Driven
  615m3/hr 1025LPM/170LPS 105 2000 Diesel Driven
  615m3/hr 1025LPM/170LPS 105 2200 Diesel Driven
17. 750 m3/hr 12500LPM/208LPS 77 1500/1800/2000 Motor Drive/Diesel Driven
  750 m3/hr 12500LPM/208LPS 88 1500/1800/2000 Motor Drive/Diesel Driven
  750 m3/hr 12500LPM/208LPS 100 1500/1800/2000 Motor Drive/Diesel Driven
  750 m3/hr 12500LPM/208LPS 120 1500/1800/2000 Motor Drive/Diesel Driven
18. 900m3/hr 15000LPM/208LPS 88 1500/1800/2000 Motor Drive/Engine Driven/*
  900m3/hr 15000LPM/208LPS 120 1500/1800/2000 Motor Drive/Engine Driven/*
19. 1200m3/hr 20000LPM/333LPS 120 1500/1800/2000 Motor Drive/Engine Driven /*
  1200m3/hr 20000LPM/333LPS 150 1500/1800/2000 Motor Drive/Engine Driven /*
  1200m3/hr 20000LPM/333LPS 180 1500/1800/2000 Motor Drive/Engine Driven /*
20. 1500m3/hr 25000LPM/417LPS 120 1500/1800/2000 Motor Drive/Engine Driven/*
  1500m3/hr 25000LPM/417LPS 150 1500/1800/2000 Motor Drive/Engine Driven/*
  1500m3/hr 25000LPM/417LPS 180 1500/1800/2000 Motor Drive/Engine Driven/*
21. 1800m3/hr 30000LPM/500LPS 120 1500/1800/2000 Motor Drive/Engine Driven /*
  1800m3/hr 30000LPM/500LPS 150 1500/1800/2000 Motor Drive/Engine Driven /*
  1800m3/hr 30000LPM/500LPS 180 1500/1800/2000 Motor Drive/Engine Driven /*
22. 3600m3/hr 60000LPM/1000LPM 120 1500/1800/2000 Motor Drive/Engine Driven/*
  3600m3/hr 60000LPM/1000LPM 150 1500/1800/2000 Motor Drive/Engine Driven/*
  3600m3/hr 60000LPM/1000LPM 180 1500/1800/2000 Motor Drive/Engine Driven/*
23. 4800m3/hr 80000LPM/1333LPS 120 750/1500/ 1800 Motor Drive/Engine Driven /*
  4800m3/hr 80000LPM/1333LPS 150 750/1500/ 1800 Motor Drive/Engine Driven /*
  4800m3/hr 80000LPM/1333LPS 180 750/1500/ 1800 Motor Drive/Engine Driven /*

Note : *Dedicated diesel engine /main engine with gear box.

We also provide fire pumps combined with diesel driven generators for almost all the above duty points and more, using the patented PLURODRIVE. Some Set specifications using PLURODRIVE for driving water pump set and (or) power alternator by a diesel engine are mentioned below.

Fire Pump with Engine and Alternator

Diesel Engine

Air-cooled or Water cooled Diesel Engine depending upon the power requirement.

PLURODRIVE

PLURODRIVE alt OR PLURODRIVE sim alt.

Pump

  • Discharge from 20 M3/Hr to 1500 M3/Hr.
  • Pressure ranging from 1.5 kg/cm2 upto 18 kg/cm2
  • Type - Horizontal or Vertical Centrifugal or centripetal or Multistage Multioutlet.
  • Material of Construction: CI / Bronze / SS, Shaft - SS / EN8
  • Sealing - Gland / Mechanical Seal

Power Alternator

Type: Slipring / Brushless type, Screen protected drip proof, Double Ball Bearings, 1500 RPM, 50 Hz, 40 Deg. Amb. Temp. 0.8pf, (1800 RPM for 60Hz) Horizontal foot mounted.

Single phase - 3 KVA to 15 KVA, Three Phase - 7.5 KVA to 1000 KVA
Reputed make equipments can be incorporated into the system.

In this arrangement, both alternate use and simultaneous use is possible.

Alternate use

Example in 19 (table below), 78 HP engine drives the pump to deliver 84 m3/hr v/s. 70mts. OR drives the alternator to give 60 KVA power.

Simultaneous use

78 HP engine drives the pump to deliver 84 m3/hr v/s. 70 mts. AND drives the 60 KVA power alternator to give 30 KVA (figures in bracket).

  ENGINE PUMP P.A.
Sr. No. HP m3/hr mts. KVA (*)
1 33 320 12 25(7)
2 33 325 14.5 25(3)
3 33 367 11 25(5)
4 47 376 19.5 35(6)
5 58 427 20 45(10)
6 68 330 38 50(3)
7 49 256 34 35(2.5)
8 33 162 25 25(9)
9 33 130 33 25(5)
10 33 60 70 25(2.5)
11 47 97 48 35(12)
12 47 73 56 35(3)
13 48 116 45 35(12)
14 33 70 62 25(1.5-2)
15 48 182 42 35(4.5)
16 48 183 45 35(2)
17 182 450 70 140(20)
18 66 70 62 50(29)
19 78 84 70 60(30)
20 83 97 70 63(30)
21 85 120 70 55 (25)
22 90 108 75 75(30)
23 114 144 88 82.5(31)
24 128 108 135 100(30)
25 120 144 95 90(32)
26 128 144 105 100(31)
27 150 144 135 110(30)
28 223 144 190 170(40)
29 76 97 56 55(31)
30 96 137 70 75(30)
31 120 171 70 90(37)
32 145 171 120 110 (10)
33 165 273 70 125(38)
34 173 273 88 125(28)
35 182 171 160 140 (22)
36 200 410 70 140(28)
37 220 410 88 160 (30)
38 260 410 105 200 (30)
39 330 615 88 250 (30)
40 385 615 105 300 (35)

Engine RPM will be generally 1800plus, P. A. = POWER ALTERNATOR

(*) KVA available in simultaneous use but will depend on engine, pump detail specification and will be conveyed along with detailed offer.

Can also supply with multi stage multi outlet Pumps.

All the above Permutations / Combinations are various possibilities and the set can be built depending upon your requirement. Set specifications will be given after hearing about Your requirement, please inquire giving details such as

  • Power required in simultaneous use and /or alternate use.
  • Pump head and capacity required.
  • Set to be used in simultaneous and (or) alternate operation.

NOTE : All figures / values given in above tables are based on the information given by Pump, Engine and Alternator manufacturers and are not binding on us.

Due to continuous developments the above information is subject to change.